MAINTENANCE
Chapter 2 Preventative Maintenance
Pumping Station Float Valve Seal Replacement Kit #105884
Removing the Existing Stem Assembly
5) Loosen the Jam Nut and remove the Lift from the Stem, then remove the Jam Nut from the
Stem.
Lift
Loosen this Jam Nut Stem
6) Loosen the Lock Nut from the Bonnet and remove the nut and the Swivel Yoke.
Lock Nut
Swivel Yoke
Loosen this Lock Nut Bonnet
7) Using an adjustable wrench, loosen and remove the Bonnet.
Bonnet
Loosen the Bonnet
from here