                       MAINTENANCE


                       Chapter 2 Preventative Maintenance


                       Pumping Station Float Valve Seal Replacement Kit #105884


                          Removing the Existing Stem Assembly
                          5)  Loosen the Jam Nut and remove the Lift from the Stem, then remove the Jam Nut from the
                              Stem.


                                                                                    Lift



                                            Loosen this Jam Nut                     Stem










                          6)  Loosen the Lock Nut from the Bonnet and remove the nut and the Swivel Yoke.

                                                                                       Lock Nut


                                                                                       Swivel Yoke


                                               Loosen this Lock Nut                    Bonnet









                          7)  Using an adjustable wrench, loosen and remove the Bonnet.



                                                                               Bonnet





                                               Loosen the Bonnet
                                               from here