Chapter 2 Preventative Maintenance
Pumping Station Float Valve Seal Replacement Kit #105884
Removing the Existing Stem Assembly
1) Remove the Float-Rod by removing the Cap Screw from the Float-Rod Connector using a
1/2” wrench.
Cap Screw
Float-Rod
2) Remove the Down-Spout.
Down-Spout
3) Remove the valve from the Bulkhead fitting on the tank.
4) Remove the two upper pins and Cotter Pins. Remove the pin that connects the Link to the
Lever and the pin that connects the Lift to the Lever.
Upper Pins Lever
Cotter Pins
Lift
Link