            Chapter 2 Preventative Maintenance


            Pumping Station Float Valve Seal Replacement Kit #105884


               Removing the Existing Stem Assembly
               1)  Remove the Float-Rod by removing the Cap Screw from the Float-Rod Connector using a
                   1/2” wrench.
                                                   Cap Screw


                       Float-Rod












               2)  Remove the Down-Spout.










                            Down-Spout






               3)  Remove the valve from the Bulkhead fitting on the tank.
               4)  Remove the two upper pins and Cotter Pins. Remove the pin that connects the Link to the
                   Lever and the pin that connects the Lift to the Lever.

              Upper Pins                                                       Lever
                                           Cotter Pins


                                                                               Lift
                                                             Link
















             2-24             Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681               1MANUL222