Page 431 - Wurth Total Catalogue
P. 431

DROP-IN ANCHOR W-ED/S



                                                                 W-ED/S
                                                                 Steel, Zinc Plated, M6 to M16
                                                                                                           13.1










       1. Areas of Application:                                 2. Advantages:
       •  Suitable for use in medium and heavy duty applications.  •  High load bearing capacity, small distances  between centers and
       •  The anchor may be used, with European technical approval, in  reinforced      from edges.
          and unreinforced normal concrete of at least property class C20/25 and   •  Slip-through installation.
          no more than C50/60, in accordance with EN 206-1:2000-12.  •  Immediately capable of  load bearing – no waiting time.
       •  Anchoring with European technical approval in uncracked concrete   •  Secure installation by applying the specified  torque during  anchoring
          (concrete pressure zone).                             •  Easily installed in overhead applications.
       •  Anchoring of lightweight ceiling panels and subceilings according
          to DIN 18168, as well as for statically comparable anchoring    3. Characteristics:
          up to 1.0 kN/m  with general building inspection approval.   •  Power controlled / torque controlled expanding anchor made from
                    2
       •  The anchor may be used for anchoring under predominantly  stationary or   zinc plated steel in sizes M6, M8, M10, M12 and M16.
          quasi-stationary loads.                               •  The attached part can be used with an attaching screw or a
       •  W-ED/S and W-ED may be used in dry indoor spaces.       threaded rod.
       •   Suitable for attachment of metal structures, metal profiles, consoles,   •  Fire resistance: F30, F60, F90 and F120.
          footplates, supports, cable trays, pipelines, railings, wood structures,   Fire strain according to DIN 4102-02: 1977-09.
          beams, purlins, etc.                                    (standard temperature-time curve).
                                                                •  Certificate: Guidelines for sprinkler systems.
























       Setting Instructions:











      AUS. pub. 11/10 ©  Drill hole  Clean borehole  Drive plug in    Anchor with   Attach

                                                                           component,
                                         until flush
                                                            expansion tool
                                                                           apply torque
                                                         06 2081
   426   427   428   429   430   431   432   433   434   435   436