Page 433 - Wurth Total Catalogue
P. 433

Wit p200



                                                                 Polyester styrene free, anchoring adhesive.
                                                                 WIT P200, 420 ml, incl. 1 static mixer.
                                                                 Art. No. 5918 200 420

                                                                Key Features :
                                                                •    For use in concrete, solid brick and perforated brick.
                                                                •  Medium duty load applications.
                                                                •   For indoor or outdoor use including wet drill holes.

                                                                Advantages :
                                                                •   No expansion stress on the concrete  Anchor close to the edges, close
                                                                  anchor spacings.
                                                                •   Resealable for multiple uses. Therefore can be used up to the end of its
                                                                  shelf life.
                                                                •   Seals drill holes and thus protects metal reinforcement.
                                                                •    ndoor usage due to low odour  styrene free .

                                                                Characteristics :
                                                                 Temperature of   Gelling - Working   Min. Curing Time in
                                                                 Concrete         Time             Dry Concrete
                                                                 5  C to 10  C    25 min           2 h
                                                                  o
                                                                         o
                                                                 10  C to 19  C   15 min           80 min
                                                                   o
                                                                          o
                                                                          o
                                                                 20  C to 29  C   6 min            45 min
                                                                   o
                                                                 30  C to 34  C   4 min            25 min
                                                                          o
                                                                   o
                                                                 35  C            2 min            20 min
                                                                   o
         Applications :














       Working load limit and installation details for a class 5.8 stud (1 kN = 100 kg)

        Anchor Size                                                M8       M10        M12       M16        M20
        Anchor Diameter                              d     mm       8        10         12        16        20
        Drill Diameter                               d o   mm      10        12         14        18        24
        Embedment Depth = Drill Depth              h  = h  mm      80        90        110       125        170
                                                    eff  1
                              Strength    20 MPa                   4.8       7.2       10.0      11.2       18.7
        Tensile Capacity Per Anchor                 N      kN
                              Grade of     32 MPa    allow         5.2       7.7       10.8      12.0       20.1
        Shear Capacity Per Anchor  Concrete    20 MPa  V   kN      5.1       8.6       12.0      22.3       34.9
                                                     allow
        Minimum Edge Distance                        c min  mm     40        50         60        80        100
      AUS. pub. 10/13 ©  Minimum Spacing             h T s min  Nm  110      120       140       160        100
                                                                   40
                                                                                        60
                                                                                                  80
                                                                             50
                                                           mm
                                                                                                            210
                                                           mm
        Minimum Component Thickness
                                                     min
        Tightening Torque
                                                                                                  60
                                                                                                            120
                                                                                        40
                                                                   10
                                                                             20
                                                     inst.
                                                         06 2131
   428   429   430   431   432   433   434   435   436   437   438