Page 435 - Wurth Total Catalogue
P. 435

PLASTIC FRAME-FIXING ANCHORS W-UR 10



                                                                Multiple attachment of non load-bearing
                                                                systems:                                   42.1
                                                                Concrete, solid and perforated bricks and aerated concrete.
                                                                W-UR
                                                                with Countersunk Screw
                                                                Dia. 10     Galvanised Steel, Yellow Chromated
                   Approvals                Test Reports        Dia. 10     Stainless Steel A4
            European          Facade            Fire            W-UR F
            Technical        Covering        Resistance         with Hexagon Screw + Pressed-on Washer
            Approval          W-UR 10           Facade          Dia. 10    Galvanised Steel, Yellow Chromated
        Multiple attachment of non load-  W-UR F 10
            bearing systems in                                  Dia. 10     Stainless steel A4
           concrete and masonry
            W-UR (F) 8, 10                    contained
                               Z-21.2-1838       in             •  Very strong twist lock.
                                             Z-21.2-1838
                                                                •  Spreading in four directions, High loads.
                                                                •  Improved power transmission: Even, continuous load distribution across
       1.  Applications:                                          the entire spreading area.
       •   The anchor may be used with a European technical approval for       •  The ETA controls a very broad range of anchoring bases (concrete,
          the multiple attachment of non-load-bearing systems (e.g. facade,   masonry of perforated and solid brick, aerated concrete)  Universal
                                                                                                        1
          suspended ceiling, etc.).                               frame-fixing anchors.
       •    W-UR, W-UR F may be anchored in the following anchoring bases:   •  The knock-in lock prevents premature spreading of the anchor during
         Normal Concrete, Masonry Walls (solid bricks, solid sand-lime bricks,   installation.
         vertically perforated bricks, perforated sand-lime bricks, hollow   •  The anchor sleeve and special screw are pre-mounted - > Less mounting
                                                                                                      1)
         blocks made of lightweight concrete, solid stones and solid blocks   effort.
         of lightweight concrete, masonry stones made of concrete) Aerated   •  Anchor type W-UR F means an additional washer is not required and
         Concrete.                                                prevents contact corrosion.
       •    Installation temperatures: Temperature in anchoring base:        •  Screw has high bending torque.
          ≥ –20°C (W-UR 10) or ≥ –40°C (W- UR 8) Temperature of       •   Improved transmission of force in solid and hollow construction
          dowel sleeve: ≥ 0°C.                                    materials.
       •   The stainless steel screw may be used outdoors and in industrial
          atmospheres and near the sea.                         3. Properties:
       •   The galvanised screw may be used outdoors or in damp rooms (careful    •  Anchoring via friction engaging between anchor sleeve and anchor
          installation) if the area near the screw head is protected against   surface.
          moisture so that penetration of moisture into the anchor shaft is not       •  W-UR 10, W-UR F 10 (galvanised steel, stainless steel):
          possible (suitable paint).                              General construction permit Z-21.2-1838.
       •   Suitable for the attachment of facade, ceiling, or roof substructures       •  W-UR 8, 10 and W-UR F 8, 10 (galvanized steel, stainless steel):
          (made of wood or steel), wood beams, wood laths, metal brackets,     European technical approval ETA-08/0190.
          metal rails, suspended ceilings, cable routes, angle brackets, profiles,     •  Dimensions: See Approval Z-21.2-1838 and ETA-08/0190.
          wall-mounted cabinets, shelf units, etc.              •  The anchor sleeve is made of high-quality polyamide.
                                                                NOTE:
       2. Advantages:                                           •  Drill perforated and hollow blocks in rotating gear (without impact
       •  Through-bolt mounting.                                  mechanism).
       •  Can be loaded immediately – no wait time.             •  For anchoring in solid brick and solid sand-lime brick, we recommend
       •  Minimal insertion torque of the anchor screw, “Slight” spreading of the   that you perform pull-out tests due to the differences in brick
         anchor, almost no turning of the anchor sleeve.          manufacturing.
                                                                •  Drilling dust is to be removed from the drill hole.
       Setting Instructions I:                                  Setting Instructions II:





     AUS. pub. 11/10 ©  Drill hole  Clean drilled hole  Set anchor and   Screw in screw  Screw in screw until   Drill hole  Clean drilled hole  Set anchor and   Screw in screw  Screw in screw until



                              screw
                                                   flush
                                                         06 2151                   screw                flush