PLASTIC FRAME-FIXING ANCHORS W-UR 10
                                                                                                              42.1

         Anchor Dimensions
         Anchor Diameter              [in mm]             W-UR 10
         Total Length                l [in mm]         80     100   115    135    160
         Maximum Mounting Height     d [mm]            10     30    45     65     90
                                      a
         Art. No.                       ®
         Plastic frame-fixing anchor W-UR  AW  30 drive
         with countersunk screw      W-UR 10 and
                                     W-UR 10 A4:     09 12 810 401  09 12 810 501  09 12 810 402  09 12 810 502  09 12 810 403  09 12 810 503  09 12 810 404  09 12 810 504  09 12 810 405  09 12 810 505
                                        ®
         Galvanised Steel, Yellow Chromated  AW  40 drive
         Stainless Steel A4
         Packing unit                Pack Qty.                     50
         Art. No.                    AW ®  25 and SW
         Plastic frame-fixing anchor W-UR F  10 drive
         with hexagon screw and      W-UR F 10:
         pressed-on washer           AW ®  40 and SW  09 12 810 601  09 12 810 701  09 12 810 602  09 12 810 702  09 12 810 603  09 12 810 703  09 12 810 604  09 12 810 704  09 12 810 605
                                     13 drive
         Galvanised Steel, Yellow Chromated  W-UR F 10 A4:
         Stainless Steel A4          SW 13                                          –
         Packing unit                Pack Qty.                     40






















































        1)  The approval takes account of the part-safety coefficients of the resistances and a part-safety coefficient of the effects of γF = 1.4. In case of a combination of tensile and transverse loads, please observe ETAG 020 Appendix C.
      AUS. pub. 11/10 ©  3)  Maximum short-term temperature.
        2)  Maximum long-term temperature.
        4)  Other brick types, raw densities, minimum compressive strengths, or temperature ranges can be found in the ETA-08/0190 approval.
        5)  The brick geometry should be matched to the approval ETA-08/0190.
        6)   If the drilled hole is created through impacting or hammering, the permissible load is to be determined via tests on the building.