PLASTIC FRAME-FIXING ANCHORS W-UR 10
                                                                                                              42.1

         Mounting Characteristic Values for Concrete and Masonry
         Anchor Diameter [in mm]                                                      W-UR 10
         Drill Nominal Diameter               d 0  [mm]                                 10
         Drill Nominal Cutting Diameter       d cut ≤ [mm]                             10.45
         Drill Hole Depth                     h ≥ [mm]                                  80
                                               1
         Setting Depth of the Anchor Sleeve   h nom  [mm]                               70
         Through-hole in Attachment Part      d f  ≤ [mm]                               10.5
         Concrete: ETA-08/0190, Multiple attachment of non load-bearing systems
         Anchor Diameter [in mm]                 2)   3)                              W-UR 10
                                                 2)
         Central Tensile Load  1)  N perm  = C12/15 [kN]  24°C /40°C 3)                 1.0
                                              50°C /80°C
                                                                                        1.0
                                                 2)
         for single anchor or anchor group    24°C /40°C 3)                             1.6
                              N perm  ≥ C16/20 [kN]  50°C /80°C 3)                      1.4
                                                 2)
         Transverse Load 1)
         Galvanised Steel     V    ≥ C12/15 [kN]                                 5.37          4.99
         Stainless Steel A4    perm
         for single anchor or anchor group
                              C12/15          s   ≥ [mm]                                 70
         Minimum Axial spacing                 min
                              ≥ C16/20        s min  ≥ [mm]                              50
         Minimum Edge spacing  C12/15         c min  ≥ [mm]                             100
                              ≥ C16/20        c min  ≥ [mm]                              70
         Edge Spacing         C12/15          c cr,N  [mm]                              140
                              ≥ C16/20        c cr,N  [mm]                              100
         Min. Component Thickness             h min  ≥ [mm]                             100
                                                                                                  2)
                  4)
                                                                                                         3)
         Masonry : ETA-08/0190, Multiple attachment of non load-bearing systems (temperature range 50°C /80°C )
        Other brick types, raw densities, minimum compressive strengths, or temperature ranges can be found in the ETA-08/0190 approval.
                                     Brick Format          Raw Density  Min. Compressive  F perm [kN] 5)  (for single anchor or anchor group)
                                                                                  2
                                                                   3
                                     [mm]                 Class [kg/dm ]  Strength [N/mm ]        W-UR 10
         Clay Brick Mz,              ≥ NF (≥ 240 x 115 x 71)  ≥ 1.8          28                    0.86
         EN 771-1, DIN 105                                                   36                    1.14
         Solid Sand-lime brick KS,                                           10                    0.43
         EN 771-2, DIN 106           ≥ NF (≥ 240 x 115 x 71)  ≥ 2.0          20                    0.71
                                                                             28                    1.0
         Solid Brick, normal concrete Vbn,                                   10                    0.57
         EN 771-3, DIN 18152         ≥ NF (≥ 240 x 115 x 71)  ≥ 2.0          20                    0.86
                                                                             28                    1.29
                             6
         Vertically perforated brick HLz ,                                   8                     0.21
         EN 771-1, DIN 105-1         ≥ 2DF (≥ 240 x 115 x 113)  ≥ 1.2        12                    0.34
         e.g. Wienerberger, Schlagmann                                       20                    0.57
                                6)
         Vert. perf. brick POROTON S11-36.5  ,
         EN 771-1, Z-17.1-812        ≥ 248 x 365 x 249        ≥ 0.9          6                     0.43
         Wienerberger, Schlagmann
         Vertically perf. brick UNIPOR WS14,                                 10                    –
         UNIPOR WS12 CORISO          ≥ 10DF (≥ 247 x 300 x 249)  ≥ 0.8
         EN 771-1, Z-17.1-883                                                12                    –
         Unipor-Ziegel Marketing GmbH
                                                                             10                    0.43
                           6)
         Perforated Sand-lime brick ,  ≥ 2DF (≥ 240 x 115 x 113)  ≥ 1.6      12                    0.57
         EN 771-2, DIN 106-1                                                 16                    0.71
         e.g. Xella                                                          10                    0.34
                                     ≥ 8DF (≥ 249 x 240 x 238)  ≥ 1.4        12                    0.43
                                                                             16                    0.57
         Hollow Block of lightweight concrete                                2                     0.09
         3K Hbl,  EN 771-3, DIN 18151  6)  ≥ 16DF (≥ 498 x 240 x 238)  ≥ 0.7  4                    0.17
         e.g. Liapor                                                         6                     0.26
         Hollow Block of lightweight concrete  ≥ 16DF (≥ 495 x 240 x 238)  ≥ 0.8  2                0.17
                 6)
         Liapor-Super-K  , EN 771-3, Z-17.1-501                              4                     0.34
         Aerated Concrete AAC                                                2 7                   0.21
                                                                                                   0.88
         Minimum intermediate distance (between single anchors or anchor groups)  s min  ≥ [mm]  250  (AAC: 250)
         Minimum axial spacing within an anchor group perpendicular to the free edge  s 1,min  ≥ [mm]  100  (AAC: 100)
         Minimum axial spacing within an anchor group parallel to the free edge  s 2,min  ≥ [mm]  100  (AAC: 100)
         Minimum edge spacing single anchor/anchor group                 c min  ≥ [mm]        100/100  (AAC: 80/100)
         Minimum component thickness                                     h min  ≥ [mm]          100  (AAC: 100)
         Anchor Dimensions
         Anchor Diameter             [in mm]              W-UR 10
         Total Length                l [in mm]        80     100    1 15   135    160
         Maximum Mounting Height     d [mm]           10     30     45     65     90
                                      a
         Art. No.                      ®
         Plastic frame-fixing anchor W-UR  AW  30 drive
         with countersunk screw      W-UR 10 and
                                     W-UR 10 A4:     09 1 2 81 0 401  09 1 2 81 0 501  09 1 2 81 0 402  09 1 2 81 0 502  09 1 2 81 0 403  09 1 2 81 0 503  09 1 2 81 0 404  09 1 2 81 0 504  09 1 2 81 0 405  09 1 2 81 0 505
         Galvanised Steel, Yellow Chromated  AW ®  40 drive
         Stainless Steel A4
         Packing unit                Pack Qty.                     50
      AUS. pub. 11/10 ©  Plastic frame-fixing anchor W-UR F  10 drive  09 1 2 81 0 601  09 1 2 81 0 701  09 1 2 81 0 602  09 1 2 81 0 702  09 1 2 81 0 603  09 1 2 81 0 703  09 1 2 81 0 604  09 1 2 81 0 704  09 1 2 81 0 605
                                       ®
         Art. No.
                                         25 and SW
                                     AW
         with hexagon screw and
                                     W-UR F 10:
                                       ®
         pressed-on washer
                                     AW
                                         40 and SW
                                     13 drive
         Galvanised Steel, Yellow Chromated
         Stainless Steel A4
                                     SW 13
                                     Pack Qty.
         Packing unit                W-UR F 10 A4:                40               –
                                                         06 2152