41-24 HEATING AND AIR CONDITIONING - HEATER WATER PIPE SOLENOID VALVE
(d). Tighten the fastening nuts at the left of the
HVAC assembly.
Torque:8~9N•m
(e). Install the pipe and tighten the fastening
bolts of the A/C pipe clamp.
Torque: 8~9N•m
14. Install the steering column beam welded assembly. (Refer to "Chapter 37 Steering
Mechanism - Steering Column Assembly, Replacement")
15. Install the instrument panel (Refer to "Chapter 52 Instrument Panel & Auxiliary
Instrument Panel - Instrument Panel, Replacement")
16. Install the heater water inlet & outlet pipes
(a). Connect the heating water inlet and outlet
pipes and tighten the clip.
17. Fill up the refrigerant (Refer to "Chapter 41
Heating And Air Conditioning - Refrigerant,
Replacement")
18. Fill up the coolant (Refer to "Chapter 16
Cooling - Coolant,Replacement")
19. Connect the negative cable of the battery
(Refer to "Chapter 18 Starting & Charging -
Battery, Replacement")
Page 1304