HEATING AND AIR CONDITIONING - REFRIGERANT                        41-25
                 REFRIGERANT


                 CHECKING


                 Leakage test can only be performed when the pressure inside the A/C system is no less
                 than 0.196MPa. However, don't inject compressed air into the system, or the moisture,
                 dust or other impurities in the air may deteriorate the drying agent or contaminate the
                 system. Check refrigerant leakage in any of the following methods:


                 1.     Measure the system pressure with manifold pressure gauge
                 (a).   It detects the defect with a manifold pressure gauge. Read the manifold pressure
                        gauge under the following conditions.
                        Test conditions:
                        Inlet temperature: 30~35℃
                        Engine RPM: 1500rpm
                        Blower RPM: Max
                        Temperature switch: Cool
                        A/C switch: ON
                        All doors open
                     NOTICE:
                 Inspect the A/C system via the diagrams and notes below, in order to judge the
                 malfunctions and malfunction causes in the air conditioning system.


                                                                   • Pressure gauge reading in normal               41
                                                                     operation:
                                                                   Low pressure:0.2~0.4MPa
                                                                   High pressure:1.2~2.0MPa