41-28                   HEATING AND AIR CONDITIONING - REFRIGERANT


           • Refrigerant not circulating (condition: cooling system works intermittently)

























                  Symptom              Possible Cause            Diagnostics                Action

                                                                                     • Check the expansion
                                                                                       valve.
                                                                                     •Blow off the dirt inside
            Vaccum at the low end    •The flow of the refrigerant                     the  expansion  valve
            and low pressure at the   is blocked by steam or                          with compressed air.
            high end. Frost or dew    dirt.                  Refrigerant  unable  to  •Replace the condenser.
            on the pipes before and   •The flow of the refrigerant   circulate       • Vacuum  the  system
            after the condensing/     is intervened by leakage                        and  Add  some
            drying can or expansion   in the expansion valve.                         refrigerant.
            valve.
                                                                                     •If any leakage in the
                                                                                      expansion valve,
                                                                                      replace it.


           • Overly refrigerant or poor radiation of condenser (condition: ineffective cooling)