HEATING AND AIR CONDITIONING - REFRIGERANT                        41-33

                                                            2.     Vacuum
                                                             (a).   Connect the connectors of the A/C
                                                                   refrigerate collecting/filling system to the
                                                                   high  and  low  ends  of  the A/C  system
                                                                   respectively.















                                                 fuwx41061

                                                            (b).   Turn on the high pressure and low pressure
                                                                   valves of the A/C refrigerate collecting/
                                                                   filling system.
                                                             (c).   Select the "Vacuum" operation of the A/C
                                                                   refrigerate collecting/filling system and set
                                                                   the timer to 15 minutes.
                                                             (d).   Start the vacuuming process of the A/C
                                                                   refrigerate collecting/filling system. When
                                                                   the set timer is reached,the system will
                                                                   stop working.                                    41
                                                             (e).   Turn off the high pressure and low
                                                                   pressure valves at the connectors of the A/
                                                                   C refrigerate collecting/filling system and
                                                 fuwx41062
                                                                   record the reading of the pressure gauge.


                  (f).   Maintain the pressure for 15 minutes. If the reading remains unchanged, it means
                        there is no leakage in the A/C pipe. Top up the refrigerant, lubricant and coolant. If
                        the reading grows, check for leakage in the A/C system.
                  (g).  Disconnect the connectors of the A/C refrigerate collecting/filling system to the high
                        and low ends of the A/C system respectively.