Page 1317 - Foton Workshop Manual - Aumark (BJ1099)
P. 1317
HEATING AND AIR CONDITIONING - A/C PIPE 41-37
A/C PIPE
REPLACEMENT
NOTICE:
• Work with dedicated service systems applicable to this model.
• Since leakage is common in the A/C system, keep the workspace well ventilated.
• Seal the disconnected pipes with plugs, to prevent impurities from entering the system.
• Use a new O-ring and apply some coolant before installation.
1. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging- Battery, Replacement")
2. Collect the refrigerant (Refer to "Chapter 41 Heating And Air Conditioning -
Refrigerant, Replacement")
3. Remove the a/c high pressure pipe
(a). Disconnect the connector of the pressure
switch.
41
(b). Unscrew the fastening bolts of the high
pressure pipe and disconnect the pipe.
Page 1317