Page 1317 - Foton Workshop Manual - Aumark (BJ1099)
P. 1317

HEATING AND AIR CONDITIONING - A/C PIPE                        41-37
                 A/C PIPE


                 REPLACEMENT
                     NOTICE:
                 • Work with dedicated service systems applicable to this model.
                 • Since leakage is common in the A/C system, keep the workspace well ventilated.
                 • Seal the disconnected pipes with plugs, to prevent impurities from entering the system.
                 • Use a new O-ring and apply some coolant before installation.


                 1.     Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
                        Charging- Battery, Replacement")
                 2.     Collect the refrigerant (Refer to "Chapter 41 Heating And Air Conditioning -
                        Refrigerant, Replacement")


                                                            3.     Remove the a/c high pressure pipe
                                                             (a).   Disconnect the connector of the pressure
                                                                   switch.













                                                                                                                    41







                                                             (b).   Unscrew the fastening  bolts of the high
                                                                   pressure pipe and disconnect the pipe.
































                                                                                                     Page 1317