41-32 HEATING AND AIR CONDITIONING - REFRIGERANT
REPLACEMENT
NOTICE:
• Use the right refrigerant service systems designed for this model.
• Since leakage is common in the A/C system, keep the workspace well ventilated.
• Keep the A/C refrigerant away from flame.
• Collect and dispose the refrigerant as required.
1. Collect the refrigerant
(a). Connect the connectors of the A/C
refrigerate collecting/filling system to the
high and low ends of the A/C system
respectively.
fuwx41061
(b). Turn on the high pressure and low pressure
valves of the A/C refrigerate collecting/
filling system.
(c). Select the "Refrigerant Collecting" option
of the A/C refrigerate collecting/filling
system. Start the system and the collecting
operation.
(d). Check the low pressure reading of the A/
C refrigerate collecting/filling system and
turn off the system when the collection is
complete.
(e). Disconnect the connectors of the A/
C refrigerate collecting/filling system to
fuwx41062
the high and low ends of the A/C system
respectively.