Page 1311 - Foton Workshop Manual - Aumark (BJ1099)
P. 1311

HEATING AND AIR CONDITIONING - REFRIGERANT                        41-31

                 5.     Check for leakage with dedicated electronic detector
                 (a).   Complicated and expensive, it can sensitively detect a certain compound, regardless
                        the intervention of other substances.Take the dedicated detector of R-134a for
                        example. It is highly sensitive and selective, which can not only accurately detect
                        the leaking points, but also identify whether the refrigerant is R-134a.Due to its high
                        sensitivity, during operation, pay attention to the contamination in the surrounding,
                        or it may lead to detection error.
                 6.     Check for leakage with fluorescent dye
                 (a).   Fluorescent dye generates fluorescence under UV, which is added into coolant or
                        refrigerant. In case of leakage, test the exterior of the system with a UV lamp and
                        find out the leaking point.
























                                                                                                                    41











































                                                                                                     Page 1311
   1306   1307   1308   1309   1310   1311   1312   1313   1314   1315   1316