41-30                   HEATING AND AIR CONDITIONING - REFRIGERANT


                  Symptom              Possible Cause            Diagnostics                Action

                                                                                     • Check and replace the
                                                             •Overly refrigerant in the
            High pressure at both    Defective expansion      low pressure pipe       expansion valve.
            high and low ends. Frost   valve                 •Dirty or blocked expansion   • Ensure the refrigerant
            or dew at the low end.                                                    volume  in the  system
                                                              valve.
                                                                                      meets the standard.


           • Defective compressor (condition: no cooling)


























                  Symptom              Possible Cause            Diagnostics                Action
                                                             • Defective compressor.  •Repair or replace the
            Overly high at the low   Internal leakage in     •Leakage in the          compressor.
            end and overly low at    compressor              damaged valve or        •Eliminate the system
            the high end.
                                                             moving part.             leakage.


           2.     Check for leakage with soap solution
           (a).   When checking for major leakage at the connection of the cooling pipe, spray some
                  soap solution around the connection and look for bubbles if any. Though it is simple
                  and convenient, it couldn't detect minor leakage.
           3.     Check for leakage with non-selective detector
           (a).   It detects all kinds of liquid or gas leakages without taking account of the chemical
                  components of the tested substance. It is easy, stable and cost-effective. However,
                  it is not applicable to large areas.
           4.     Check for leakage with halogen leak detector
           (a).   With specific sensors, it detects the compounds containing minor volume of F, Cl, Br
                  and I in the air, regardless the intervention of other substances. It is highly sensitive
                  and effectively minimizes detection errors. In case of large areas, the min. detection
                  threshold is 5g/year; and for spot detection, it is 1.5g/year (i.e., it can detect a
                  leaking point with the leakage volume of 1.5g a year).