41-34 HEATING AND AIR CONDITIONING - REFRIGERANT
3. Fill up the refrigerant
(a). Connect the connectors of the A/C
refrigerate collecting/filling system to the
high and low ends of the A/C system
respectively.
(b). Vacuum the A/C system.
(c). Fill up the coolant.
(d). Select the "Refrigerant Filling" option of the
A/C refrigerate collecting/filling system and
set the filling volume.
A/C refrigerant filling volume: 700±50g
fuwx41061
(e). Turn on the low pressure valve at the
connector of the A/C refrigerate collecting/
filling system, start the system and top up
the refrigerant.
(f). Watch the display of the A/C refrigerate
collecting/filling system.When the filling
volume reaches the set value, the display
will inform you that the filling is complete.
fuwx41062
(g). Turn off the low pressure valve at the
connector of the A/C refrigerate collecting/
filling system.
(h). Disconnect the connectors of the A/
C refrigerate collecting/filling system to
the high and low ends of the A/C system
respectively.
(i). Ensure there is no leakage in the A/C
system.
(j). Refrigerant filling is complete.
fuwx41062