Page 1316 - Foton Workshop Manual - Aumark (BJ1099)
P. 1316
41-36 HEATING AND AIR CONDITIONING - COOLANT
2. Fill up the coolant
(a). Filling Volume of A/C Refrigerant & Lubricant.
Replace A/C Replace the Replace Replace A/C
Service Item
compressor condenser evaporator pipe
Filling Volume of Same volume as Add 20% of the rated Add 33% of the rated Add 27-33% of the
A/C Coolant removed coolant coolant volume coolant volume rated coolant volume
(b). Connect the connectors of the A/C
refrigerate collecting/filling system to the
high and low ends of the A/C system
respectively.
(c). Vacuum the A/C system.
fuwx41061
(d). Turn on the high pressure and low pressure
valves of the A/C refrigerate collecting/
filling system.
(e). Top up the coolant according to the user's
manual of the A/C refrigerate collecting/
filling system and ensure the filling volume
of the coolant meets the standard.
(f). Disconnect the connectors of the A/
C refrigerate collecting/filling system to
the high and low ends of the A/C system
respectively.
fuwx41062
Page 1316