41-26                   HEATING AND AIR CONDITIONING - REFRIGERANT


           • Steam in the system (condition: no cooling intermittently)

























                  Symptom              Possible Cause            Diagnostics                Action

                                     Steam  in  the  cooling
                                     system  is  condensed  •Fluid reservior is overly
            During operation, the    in the expansion valve   saturated.             •Replace the condenser.
            pressure at the low end   hole and the return  •Steam is condensed in  •Discharge the steam
            is sometimes vacuum,     pipe stops working from   the  expansion  valve  inside the return pipe.
            and is normal in other   time to time.When it     hole  and  blocks  the  •Add some refrigerant.
            times
                                     is melted, it returns to   flow of the refrigerant.
                                     normal.
           • Insufficient cooling (condition: ineffective cooling system)