DIAGNOSIS-POWER WINDOW                                  62-63

                 3.     Check harness and connector (Assistant driver door power window motor-BCM
                            control unit)


                 (a).   Ignition switch:"LOCK".
                 (b).   Unplug the assistant driver door power window motor G01.
                 (c).   Disconnect the BCM control unit connector C57.                                              62


                                                            (d).   Measure the resistance with the multimeter.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                      G01(5) - C57(D32)           < 2 Ω





                 Is the inspection result normal?
                 Yes>To step4.
                 No >Repair or replace the communication harness between No.5 pin of assistant driver
                         door power window motor G01 and No. D32 of  BCM control unit C57.


                 4.     Check harness and connector (Assistant driver door power window motor-front
                        window fuse)


                 (a).   Ignition switch:"LOCK".
                 (b).   Unplug the assistant driver door power window motor G01.


                                                            (c).   Measure the resistance with the multimeter.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)


                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                         G01(3) - F13             < 2 Ω





                 Is the inspection result normal?
                 Yes>To step5.
                 No >Repair or replace the harness.