Page 2339 - Foton Workshop Manual - Aumark (BJ1099)
P. 2339

DIAGNOSIS-CIGARETTE LIGHTER                              62-287

                                                            (b).   Disconnect the connector C33 of the
                                                                   cigarette lighter.





                                                                                                                    62
















                                                            (c).   Measure the resistance with the multimeter
                                                                   on the resistance range.
                                                                        Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by       Standard value
                                                                          multimeter

                                                                       C33(1) -Grounding           < 2 Ω



                 Is the result normal?
                 Yes>To step4.
                 No >Repair or replace the harness.


                 4.        Check the harness and the connector (cigarette lighter-cigarette lighter fuse)


                 (a).     Ignition switch:"LOCK".
                 (b).   Disconnect the connector C33 of the cigarette lighter.


                                                            (c).   Measure the resistance with the multimeter
                                         F39  F24  F25  F26  F27  F28  F29
                                         F38                       on the resistance range.
                   OFF           T.S     F37  F19  F21  F18  F20  F22  F23
                                         F36         R07
                                   C05                                  Standard resistance: (check whether there
                                              F11  F12  F13  F14  F15      is an open circuit)
                                              F01  F02  F03  F04  F05  F06  F07  F08
                            C33
                                                                     Connect the pin by
                       1                                                  multimeter          Standard value
                       2           Ω
                       3                                                  C33(2) - F20             < 2 Ω
                                                 fuwx6 7572










                                                                                                     Page 2339
   2334   2335   2336   2337   2338   2339   2340   2341   2342   2343   2344