Page 2433 - Foton Workshop Manual - Aumark (BJ1099)
P. 2433

DIAGNOSIS-LIGHTING SYSTEM                               62-381

                 Is the result normal?
                 Yes>To step 3.
                 No >Replace the bulb.


                 3.     Check small light switch of combination switch
                                                                                                                    62
                 (a).   Disconnect combination switch connector C16.
                 (b).   Turn combination switch to "Small light" position.


                                                            (c).   Use a multimeter to measure that the
                                                                   continuity between No. 11 terminal and No.
                   OFF           T.S
                                                                   19 terminal of combination switch shall be
                                      Ω
                                                                   existed.

                                                  C16

                          10  9  8  7  6  5  4  3  2  1
                          20  19  18  17  16  15  14 13 12  11
                                                 fuwx62 864

                 Is the inspection result normal?
                 Yes>To step 4.
                 No >Replace the combination switch.


                 4.     Check the harness disconnection


                 (a).   Disconnect combination switch C16, body controller C56, body controller C58.


                                                            (b).   Use a multimeter to measure the resistance
                                                                   between No. 19 terminal of combination
                   OFF           T.S
                                            Ω                      switch C16 and the ground.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)
                                        C16
                    10  9  8  7  6  5  4  3  2  1                    Connect the pin by
                                                                         multimeter
                    20  19  18  17  16  15  14 13 12  11                                     Standard value
                                                 fuwx62 865
                                                                     C16(19) - Grounding           ≤ 2 Ω





















                                                                                                     Page 2433