62-378 DIAGNOSIS-LIGHTING SYSTEM
3. Check harness disconnection (LF combination lamp - ground)
(a). Disconnect LF combination lamp connector A28.
(b). Use a multimeter to measure the resistance
between No. 7 terminal of connector A28
OFF T.S
and the ground.
A28
Standard resistance: (check whether there
Ω 1 2 3
4 5 6 is a short circuit)
7 8 9
Connect the pin by Standard value
multimeter
fuwx62 863
A28(7) - Grounding < 2Ω
Is the inspection result normal?
Yes>Find the causes from other symptoms.
No >Repair the harness disconnection between connector A28 and the ground.