Page 2434 - Foton Workshop Manual - Aumark (BJ1099)
P. 2434

62-382                           DIAGNOSIS-LIGHTING SYSTEM


                                                      (c).    Use a multimeter to measure the resistance
                                                              between No. 11 terminal of combination
             OFF            T.S
                                    Ω                         switch C16 and No. E5 terminal of body
                                                              controller C58.
                                                              Standard resistance: (check whether there
                              C58
                                                              is an open circuit)
                                             C16
               16 15  14  13 12  11 10 9  8  7  6  5  4  3  2  1
                                    10  9  8  7  6  5  4  3  2  1
               32  31  30 29 28  27  26  25  24 23 22 21  20 19 18 17
                                    20  19  18  17  16  15  14 13 12  11  Connect the pin by
                                           fuwx62 866                                   Standard value
                                                                    multimeter
                                                                 C16(11) - C58(E5)            ≤ 2 Ω


                                                      (d).    Use a multimeter to measure position lamp
                                                              fuse F6 in the indoor fuse box and No. 5
                                                              terminal of body controller C56.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)


                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                               Position lamp fuse F6         ≤ 2 Ω
                                                                     - C56(5)

           Is the inspection result normal?
           Yes>To step 5.
           No >Repair or replace harness.


           5.     Check harness short circuit to the grounding


           (a).   Disconnect body controller C56.


                                                      (b).    Use a multimeter to measure the resistance
                                                              between No. 5 terminal of body controller
             OFF            T.S
                                      Ω                       C56 and the ground.
                                                              Standard resistance: (check whether there
                                                              is a short circuit)
                            C56
                                                               Connect the pin by
               1 2  3    4 5
                                                                   multimeter
               6 7 8  10  1112                                                          Standard value
                                           fuwx62 868
                                                                C56(5) - Grounding          > 1 MΩ

           Is the inspection result normal?
           Yes>Find the causes from other symptoms.
           No >Repair harness short circuit to ground between connector C56 and position lamp fuse.







                                                                                                     Page 2434
   2429   2430   2431   2432   2433   2434   2435   2436   2437   2438   2439