Page 2455 - Foton Workshop Manual - Aumark (BJ1099)
P. 2455

DIAGNOSIS-LIGHTING SYSTEM                               62-403

                 Symptom description:
                 Switch on vehicle door and interior light, neither step lamp and interior light turns on.


                 Diagnosis Procedure


                 1.     Check the fuse                                                                              62


                 (a).   Ignition switch:"OFF".
                 (b).   Open interior fuse box cover.
                 (c).    Take out energy saving power fuse F36(10A).
                     NOTICE:
                 A special fuse puller is required for removing the fuse. It shall not be directly pulled out by
                 hand, which will damage the fuse easily.


                                                            (d).   Check if the middle fuse wire of position
                                                                    lamp fuse F36(10A) is fusing.
                     Disconnect            Normal










                                                 fuwx62802

                 Check if the fuse is fusing.
                 Yes>Replace the fuse.
                     NOTICE:
                 While replacing the fuse, be sure to replace it with a fuse of the equal ampere rating value.
                 The backup lamp fuse value of this vehicle type is 10A.
                 No >To step 2.


                 2.     Check the harness disconnection


                 (a).   Disconnect body controller C56.


                                                            (b).   Use a multimeter to measure the voltage
                   ON                                              between No. 10 terminal of connector C56
                                 T.S
                                            v                      and the grounding.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)
                                      C56
                     1 2  3        4 5                               Connect the pin by
                     6 7 8    10  1112                                                       Standard value
                                                                         multimeter
                                                 fuwx62 884
                                                                     C56(10) - Grounding        Battery volt





                                                                                                     Page 2455