62-546                       DIAGNOSIS-ENGINE CONTROL SYSTEM


           Diagnosis Procedure
               Notice:
           • Before performing the diagnosis, ensure that the engineECUand the coolant temperature
             sensor are connected properly.
           • Before performing a diagnosis and testing, refer to circuit diagrams and component
             information.
           • Before performing the test, check whether the connector pins are ruptured, loosened or
             corroded, to ensure proper contact of pin.
           • If the connection is good, check the signal voltage of the sensor as moving the connector
             and wiring harness. If a fault occurs, the corresponding voltage value display will
             changeon the diagnostic tool.

           1.     DTC Test


                                                      (a).    Ignition switch: LOCK .
                                                       (b).   Connect the diagnostic device.
                                                       (c).   Ignition switch: ON .
                                                       (d).   Using the diagnostic tool reads the fault
                                                              code.
                                                       (e).   Is there a fault code of coolant temperature
                                                              sensor related?











                                           fuwx62176


           Is the inspection result normal?
           YES>There is an intermittent fault.
           No > To step 2.


           2.     Read the data from the diagnostic tool


           (a).   Ignition switch: LOCK .
           (b).   Connect the pin1and2of coolant temperature sensor connectorE18 .
           (c).   Ignition switch: ON。
           (d).   Read the coolant temperature value displayed on the diagnostic instrument.
                  Test results :

                          Diagnostic testing                               Standard value

                              Temperature                                   Approx 130° C