DIAGNOSTICS - ASSEMBLY INSTRUMENT                           04-943

                                                           (c)    Use a multimeter to measure the voltage
                                                                  between pins 1 and 3 of connector C013 of
                                                                  the combination instrument C013 and the
                                                   C013
                                                                  ground.
                                                                  Standard voltage
                            16 15  14  13 12  11 10  9  8  7  6  5  4  3  2  1
                            32 31  30  29 28 27  26  25  24  23  22  21  20  19  18 17
                                                            Multimeter connection          Standard value            04
                                                                C013 (1) -ground
                              1  3                                                          Battery voltage
                                                                C013 (3) -ground





                                                 ftwxd041039


                 Check whether the result is normal?
                 Yes> go to step 3
                 No > If battery voltage is unavailable in pin 3 of connector C013 of combination
                 instrument, repair the open circuit of the circuit between F7 (7.5A) and pin 3 of
                 connector C013 of the combination instrument. If battery voltage is unavailable in pin
                 1 of connector C013 of combination instrument, repair the open circuit of the circuit

                 between F26(10 A) and pin 1 of connector C013 of the combination instrument.

                 3 .    Check the ground circuit of combination instrument
                 (a)    Ignition Switch: OFF.

                                                           (b)    Use a multimeter to measure the resistance
                                                                  between pins 3 of connector C013 of the
                                                                  combination instrument and the ground.
                                                   C013
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)
                            16 15  14  13 12  11 10  9  8  7  6  5  4  3  2  1
                            32 31  30  29 28 27  26  25  24  23  22  21  20  19  18 17
                                                            Multimeter connection          Standard value
                                                                C013 (2) -ground                ≤ 2 Ω
                               2






                                                 ftwxd041419


                 Check whether the result is normal?
                 Yes> replace combination instrument assembly.

                 No > Repair the circuit between pin 2 of connector C013 of combination instrument
                 and the ground.

                 4 .    Check the power-supply short circuit of combination instrument






                                                                                                        Page 1089
   1084   1085   1086   1087   1088   1089   1090   1091   1092   1093   1094