Page 1578 - Foton Workshop Manual - Tunland (AT)
P. 1578

20-12                         STARTING AND CHARGING - BATTERY


                    Display Zone                   Determination                      Treatment
                                                                             20. Start & charge - battery,
                                                                             use and maintenance ”)


           3 .    Voltage test.
                  The following table is derived using the digital multimeter test table.

                       Voltage                     Determination                      Treatment
                    Above 12.5V                        Normal                        Go on using

                                                                              Additional charge (refer
                                                                              to“ Chapter 20. Start &
                     11.5 - 12.5V                   Undercharge
                                                                             charge - battery, use and
                                                                                 maintenance ”)
                                                                            To be further checked after
      20
                                            Over-discharge or internal      charging (refer to“ Chapter
                    Below 11.5 V
                                                        failure             20. Start & charge - battery,
                                                                             use and maintenance ”)