Page 21 - Foton Workshop Manual - Tunland (AT)
P. 21
INTRODUCTION - GENERAL SERVICE GUIDELINE 01-15
(a) When removing or installing the intake air system parts, close the opening caused by 01
the removed part with clean cloth or tape.
(b) When installing the intake system parts, ensure there is no metal fragment.
6 . Service on Hose Clip
(a) Before removing the hose, check the depth
of the connector and the position of the clip,
to ensure correct reinstallation.
(b) If any distortion or dent in the hose, replace
it.
(c) If the hose is reusable, place the spring clip
on the original mark.
(d) For spring clip, after installation, adjust its
position by pushing towards the arrow
direction.
7 . Catalyst Converter
NOTICE
If plenty of fuel flows into the catalyst converter without combustion, the catalyst
converter will be overheated, which may cause fire. In order to prevent such accident,
follow the precautions below during service.
(a) Don't idle the engine for more than 20 minutes.
(b) Avoid unnecessary sparking test.
• Don't do any sparking test unless necessary. If it is necessary, complete it as
soon as possible.
• Don't press the accelerator when doing sparking test.
(c) Don't perform an engine stress test on an ongoing basis. Complete it as soon as
possible.
(d) Don't run the engine when the fuel tank is nearly empty, or it may cause extra burden
to the catalyst converter when the engine is out of service.
Page 21