Page 854 - Foton Workshop Manual - Tunland (AT)
P. 854

04-708               DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM

                                                      (b)    Use multimeter to measure the resistance
                                                             between stitch D6 of connector C035 of body
                                                             controller and the ground.
                                                      Standard resistance (check whether there is
                                                      short circuit)

      04                                                     Multimeter
                                                                                      Standard value
                                                             connection
                                                        C035 (D6) — ground                < 2 Ω










           Check whether the result is normal?
           Yes> go to step 5
           No> replace body controller


           5 .    Check harness and connector (body controller-power window switch, left front
                  door )
                                                      (a)    Disconnect connector J008 of power window
                                                             switch, left front door.























                                                      (b)    Disconnect connector C035, body controller.

























                                                                                                         Page 854