DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM                       04-707

                                                           (a)    Disconnect connector J008 of power window
                                                                  switch, left front door.







                                                                                                                     04














                                                           (b)    Use multimeter to measure the resistance
                                                                  between stitch 11 of connector J008 of power
                                                                  window switch of left front door and the
                                                                  ground.
                                                           Standard electrical resistance (check whether
                                                           there existent an open circuit)

                                                                   Multimeter
                                                                                           Standard value
                                                                  connection

                                                                 J008(1)-ground                 < 2 Ω







                 Check whether the result is normal?
                 Yes> go to step 4

                 No > Maintenance or replace harness.

                 4 .    Check circuit of body controller

                                                           (a)    Disconnect connector C035, body controller.