Page 857 - Foton Workshop Manual - Tunland (AT)
P. 857

DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM                       04-711

                                                           (b)    Use multimeter to measure the resistance
                                                                  between stitch 7 of connector J007 of lock
                                                                  assy of left front door and the ground.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                                 Multimeter                                          04
                                                                                      Standard value
                                                                 connection
                                                               J007(7)-ground              < 2 Ω










                 Check whether the result is normal?
                 Yes> go to step 8
                 No > Maintenance or replace harness.


                 8 .    Check circuit of body controller

                                                           (a)    Disconnect body controller C036 connector.



















                                                           (b)    Use multimeter to measure the resistance
                                                                  between. stitches E27, E28 of connector C036
                                                                  of the body controller and the ground.
                                                                  Standard resistance (check whether there
                                                                  is short circuit)

                                                                 Multimeter
                                                                                      Standard value
                                                                 connection

                                                             C036(E27)-ground
                                                                                           < 2 Ω
                                                             C036(E28)-ground






                 Check whether the result is normal?






                                                                                                         Page 857