Page 856 - Foton Workshop Manual - Tunland (AT)
P. 856

04-710               DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM

                                                      (b)    Use multimeter to measure the resistance
                                                             between stitch 2 of connector J008 of power
                                                             window switch of left front door and its stitch
                                                             11 .

                                                             Standard voltage

      04
                                                                       Multimeter       Standard
                                                       Conditions
                                                                       connection         value

                                                          central

                                                           door       J008(2)-J008(1)
                                                        lock-closed                      < 2 Ω
                                                          central
                                                                      J008(2)-J008(1)
                                                       door -opened


           Check whether the result is normal?

           Yes> go to step 7
           No> Replace power window switch, left front door.

           7 .    Check harness and connector (lock assy of left front door-ground)


                                                      (a)    Disconnect connector J007 of left front door
                                                             lock assy.