Page 858 - Foton Workshop Manual - Tunland (AT)
P. 858

04-712               DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM

           Yes> go to step 9

           No> replace body controller

           9 .    Check harness and connector (body controller-power window switch, left front
                  door )

      04                                              (a)    Disconnect connector J007, lock assy, left
                                                             front door.























                                                      (b)    Disconnect body controller C036 connector.



















                                                      (c)    Use multimeter to measure the resistance
                                                             between stitches 19 and 10 of connector
                                                             J007of lock assy for the left front door and
                                                             stitches E27, E28 of connector C036 of body
                                                             controller.
                                                             Standard resistance (check whether there
                                                             is short circuit)

                                                           Multimeter
                                                                                Standard value
                                                           connection

                                                       J007(9)-C036(E28)
                                                                                     < 2 Ω
                                                       J007(10)-C036(E27)




           Check whether the result is normal?
           Yes> go to step 10




                                                                                                         Page 858
   853   854   855   856   857   858   859   860   861   862   863