Page 2064 - Foton Workshop Manual - Sauvana
P. 2064

62-12          DIAGNOSIS-SUPPLEMENTAL INFLATABLE RESTRAINT SYSTEM (SRS)


           4.     Check The Harness Disconnection


           (a).   Disconnect SR ECU connector C27 and clock spring C18.


                                                      (b).    Check the resistance value between clock
                                                              spring connector C18 and SRS ECU
                                                              connector C27.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                                Connect the pin by      Standard value
                                                                    multimeter
                                                                  C18(1) - C27(10)            ≤ 2 Ω

                                                                  C18(2) - C27(11)            ≤ 2 Ω







           Is the inspection result normal?
           Yes>To step 5.
           No >Repair or replace the harness.


           5.     Check clock spring short circuit to ground


           (a).   Confirm to turn ignition switch off, and disconnect battery terminal negative for more
                  than 90s.
           (b).   Disconnect clock spring connector C18 and driver airbag connector.


                                                      (c).    Check the resistance value between clock
                                                              spring connector C18 and driver airbag
                                                              connector.
                                                              Standard resistance: (check whether there
                                                              is a short circuit)

                                                                Connect the pin by      Standard value
                                                                    multimeter

                                                                 C18(1) - Grounding          ≥ 1MΩ
                                                                 C18(2) - Grounding          ≥ 1MΩ

           Is the inspection result normal?
           Yes>To step 6.
           No >Repair or replace the harness.









                                                                                                     Page 2064
   2059   2060   2061   2062   2063   2064   2065   2066   2067   2068   2069