Page 2083 - Foton Workshop Manual - Sauvana
P. 2083

DIAGNOSIS-POWER WINDOW                                  62-31
                 BASIC INSPECTION


                   Procedures                 Inspection contents                            Action


                                   Check battery voltage                Yes     To step 2
                                   • The battery must show voltage of           Charge or replace the battery. See
                         1                                                                                          62
                                     12 V or more.                      No      "Section 18A Starting and Charging
                                   Is the inspection result normal?             - Battery"
                                   Check Front Left Door Window         Yes     To step 3
                                     Regulator
                                   • When ignition switch is in "ON"
                                     gear, use main door control
                         2           switch to operate the rise and
                                     fall of left front door window     No      See Symptom Table
                                     glass regulator in the No. 1 gear
                                     position.
                                   Is the inspection result normal?

                                   Check left front window glass        Yes     To step 4
                                   regulator automatic fall function
                         3         •When the ignition switch is in "ON"
                                     gear.                              No      See Symptom Table
                                   Is the inspection result normal?
                                   Check Front Right Door Window        Yes     To step 5
                                     Regulator
                                   • Use the main door control switch
                         4
                                     to control the rise and fall of right   No  See Symptom Table
                                     front door window regulator.
                                   Is the inspection result normal?

                                   Check Front Right Door Window        Yes     To step 6
                                   Regulator
                                   • Use the right front door window
                         5           control switch to control the rise
                                     and fall of right front door window   No   See Symptom Table
                                     regulator.
                                   Is the inspection result normal?




















                                                                                                     Page 2083