Page 2084 - Foton Workshop Manual - Sauvana
P. 2084
62-32 DIAGNOSIS-POWER WINDOW
Procedures Inspection contents Action
Check automatic window closing Yes To step 7
function
• When ignition switch is in "OFF"
gear, close all doors and lock the
6 lock, after about 2s, make power
window to complete automatic No See Symptom Table
window closing according to the
left side and then right side order.
Is the inspection result normal?
Check window lock switch Yes To step 8
• Press the window lock switch on
the main control switch of doors.
• Use the right front door window
7 control switch to control the rise
and fall of right front door window No See Symptom Table
regulator.
Check whether the right front door
window regulator works.
Check window lock switch Yes See Symptom Table
• Press the window lock switch on
the main control switch of doors
again.
• Use the right front door window Replace the right front door window
8 control switch Refer to "Chapter
control switch to control No
the rise and fall of right front door 56 Interior and Exterior-Front/Rear
window regulator. Finisher, Replacement"
Check whether the right front door
window regulator works.
Page 2084