18. Install the starter shell retaining bolts
Torque: 8~10N•m
fuwx18A028
19. Install the magnetic switch and tighten
retaining bolts
Torque: 8~10N•m
18A
fuwx18A027
20. Connect the magnetic coil lead nut from
magnetic switch
Torque: 14~16N•m
fuwx18A026
21. Connect the starter electrical wire
connecting nut
Torque: 18~20N•m
22. Connect the starter control wire connector
fuwx18A020