17-24         COOLING - SUPPLY AND RETURN PIPE OF AIR CONDITIONING SYSTEM

                                                      6 .    Unscrew the fixing bolt of the air
                                                             conditioning system supply pipe and
                                                             vacuum pump, disconnect the air
                                                             conditioning system supply pipe and
                                                             vacuum pump.
                                                      7 .    Release the fixing buckle of the air
                                                             conditioning system supply pipe and
                                                             thermostat housing, disconnect the air
                                                             conditioning system supply pipe and
                                                             thermostat housing.



      17




                                                      8 .    Release the fixing buckle of the air
                                                             conditioning system return pipe and water
                                                             pump, remove the air conditioning system
                                                             supply and return pipe














                                                      9 .    Reset the fixing buckle of the air
                                                             conditioning system supply and return
                                                             pipe and water pump.