04-98 DIAGNOSTICS - TRANSFER GEAR
(b) Use multimeter to measure the resistance
between pin 3 of speed sensor E001
connector and ground. Standard resistance
(check whether there is short circuit)
Multimeter connection Standard value
04
E001 (3) - ground ≥ 1 MΩ
E001
ftwxd041353
(c) Use multimeter to measure the resistance
between No.3 stitch speed sensor E001
connector and No.8 stitch of C013 connector.
Standard electrical resistance (check
C013
whether there existent an open circuit)
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
Multimeter connection Standard value
E001 (3) - C013 (8) ≤ 2 Ω
ftwxd041354
Check whether the result is normal?
Yes> replace combination instrument assembly.
No > Repair signal circuit between pin 3 of speed sensor E001 connector and pin 8 of
combination instrument C013 connector