Page 43 - AP2464B E-BOOK (KKR2 TOWER)
P. 43

DESIGN AND SIZE OF ELEVATOR




           KKR is using the shuttle lift as their elevator concept in their building. The building is divided into
            two zones, which is lower zone and high zone. The lower zone is the elevator from the ground
                           level to 18 . The high zone is elevator from 18 floor to 36 floor.
                                                                                        th
                                                                            th
                                      th
              General Specification of Elevator                   General Specifications of Control Room

             For office building, usually the waiting             2 rooms of control rooms
                                                                                             th
              time for the elevator is 25 to 30 seconds            From ground level to 18 floor and from
             1600 kg / up to 21 persons                            18 to 36 floor
                                                                              th
                                                                       th

                            Jabatan Kerja Raya’s Building have 16 total elevators,
                            plus one elevator for services lift in the building.  Why
                                    there is many elevators in this building?







         Factors affecting the                                                                 ELEVATOR
          design and size of                                                                    MACHINE
                 elevator:
                                                                                                   ROOM
                                                                                                LOCATED

    1. Type of building used                                                                    AT FLOOR
    • Government Building, Capitol
       Building,   and   Office,   these                                                          18 AND
       types of building can show the                                                           FLOOR 36
       busyness of the visitor and
       employees used the elevators
       during office hours.


    2. Population of the building
    • Since this building is main
       building for Jabatan Kerja Raya
       Malaysia, the population of the
       employees and visitor to the
       building will affect the size and
       number of elevators used
    • Number of populations also
       affect when there is a peak
       hour in the buildings such as
       early in the morning, lunch hour
       and during the end of office
       hours.                                          CONTROL SYSTEM,                    GEARLESS ELEVATOR
                                                       DRIVE AND BRAKE                            MACHINE
                                                             SYSTEM
   38   39   40   41   42   43   44   45   46   47   48