Page 61 - SMM2 eBOOK
P. 61
J.12 Mouldings and enrichments (cont'd)
2. Mouldings and enrichments on linear items of stonework shall be given in the description
stating the girth and profile. Stops, mitres, retUrned ends and the like shall be deemed to
be included.
3. Mouldings and enrichments on enumerated items of stonework shall be given in the
description stating the girth and profile. Stops, mitres, returned ends and the like shall be
deemed to be included.
4. Projecting moUldings and enrichments shall be so described and the extra stone reqUired
shall be deemed to be included.
J.13 Ornaments
Ornaments shall be enumerated stating the size and profile. The extra stone required for
projecting ornaments shall be deemed to be included.
J.14 Small panels
1. Stones fomming small panels defined as panels not exceeding 0.10m2 shall each be
enumerated stating the size. Those which are flUsh shall be so described. Those which
are sunk or projecting shall each be so described stating the set-back or projection.
2. Small panels worked on other stones shall be enUmerated stating the size and the set-
back on projection. The extra stone reqUired for projecting panels shall be deemed to be
inciUded.
J.15 Pilasters
1. Stones fomming pilastens shall be given in metres (measured vertically) stating the width
on face, the total thickness and the projection beyond the face of the wall. Battered
pilasters and those sunk to entasis shall each be so described.
2. Caps and bases to pilasters shall each be enumerated separately stating the size and
profile.
J.16 Quoins and jambs
Stones forming quoins and jambs shall each be given separately in metres (measUred
vertically) stating the width on face and the thickness. Those which are battered or projecting (or
both) shall each be so described.
J.17 Columns
1. Independent columns shall be given in metres (measured vertically) stating the size of the
cross-section or the diameter. Those sunk to entasis shall be so described stating the
greatest size or diameter.
2. Stones fomming attached columns shall be given in metres (measUred vertically) stating
the width on face, the total thickness or the diameter of the projection. Those sunk to
entasis shall be so described stating the greatest diameter.
3. Caps and bases to colUmns or attached colUmns shall each be enUmerated separately
stating the size and profile.
58