Page 764 - PPL-engelsk 2025
P. 764

Aircraft general knowledge



                8.12.2.6     Fuel Flow meter


                A  fuel  flow  meter  shows  the  current  fuel  consumption,  and  via  tables  for

                revolutions, manifold pressure and flight altitude lean to the correct fuel flow.




                Some fuel flow meters show fuel consumption on one side

                and intake pressure on the other side (ManPress).


                Manifold pressure gauges are used for injection engines.




                Power  setting  is  a  combination of  revolutions  and  intake  pressure  (manifold

                pressure).


                Required, among other things, in aircraft with constant speed propellers.




                8.12.2.7    CHT

                A CHT (cylinder head temperature) measures the cylinder

                head temperature of the hottest cylinder.


                If  the  temperature  becomes  too  high,  the  fuel  mixture

                must be made richer, or the cooling must be opened if the

                Cowl Flaps (regulation of cooling air that flows around the

                cylinders) have been closed.




                If the aircraft is used for towing banners or gliders, it must be equipped with

                cylinder temperature gauge and you have to monitor the instrument to avoid

                overheating the engine. When towing the airspeed will be lower, the output of

                the engine will be higher and if you are not carefull you might create an engine
                failure.





                Back to table of contents



             Flyveteori PPL(A)(UL)/LAPL             Henning Andersen, Midtjysk Flyveskole© 2025               764