Page 1087 - Flipbook_SolidDesignSoutheast2020
P. 1087
Iris Pipeline X-ray provides
• Unparalleled accuracy, precision and speed.
• Traceability and storage of inspection results.
• Fully auditable, reject integrity measures as standard.
• Online test methods to support compliance with
customers’ COP.
Simple and robust
• Robust precision made, lift-out pipe sections.
• No fuss.
Easy to clean
• Excellent visual and physical access.
• Built to the highest care/food grade standards.
• Easy clean, sloped surfaces allow water to run off
and speed up drying time.
Model Specification IRIS (150, 250, 300)
X-ray output 30kV to 100kV, 1.0mA to 3.0mA
Detector pixel size 0.4 mm
Safety Less than 1.0 Sv/h
Display 15 inch colour Thin Film Transistor (TFT) LCD
Operation method Drag and drop functionality touch panel with physical e-stop and reset button
Iris 150 transfer pipe diameter (1½ Inch / 38mm ID)
Iris 250 transfer pipe diameter (2½ Inch / 60mm ID)
Iris 300 transfer pipe diameter (3 Inch / 75mm ID)
Preset memory 500 maximum
Power requirements 220 to 240 Vac +/- 10% Single Phase 50/60 Hz
Mass 450kg
Environmental conditions Temperature 0c to 40c, relative humidity 30% to 85%
Max filling pressure 50 bar
Protection class IP66 grade equipment
Exterior Stainless steel (AISI SUS 304)
Reject device Stainless steel, 3 way electric driven ball valve
Communication USB, remote ethernet connectivity and system status control
Calibration 5-second automatic start up calibration, self-calibration during operation
Environment class ESOS ready
CE compliant Yes
UL/CSA compliant Yes
Mechanical Construction
• Sheet stainless steel frame • High care, height adjustable wheels • Sealed for life bearings.