Page 1088 - Flipbook_SolidDesignSoutheast2020
P. 1088

Speci cation





               Reject integrity measures                       Line integration
               •  Servo driven.                                •  Sleep mode fitted to reduce energy consumption.
               •  Time out control / reject-track software.    •  Configurable Inputs and Outputs (IO).
               •  Reject confirmation.                          •  Level D safety circuit.
               •  Electronic ‘Reject Mechanism in Place’ monitor.
               •  A four beacon light stack in a stainless steel protective cage.  Management information
                                                               As standard, statistical data is available to be sent, on demand,
               Single point operator interface                 to your network for storage and later use.
               •  15.1” menu driven Thin Film Transistor (TFT) full colour display
                                                               In addition to being able to connect to your network, the system
                  with drag and drop functionality.
                                                               is also fitted with the USBStore data capture system, which is a
               •  Display resolution: 1:12,000.
                                                               simple yet highly effective way in which to manage this data .
                                                               The system collects and manages the statistical data and results
               Electronic control system
                                                               generated for all measured attributes. As with the network
               •  Industrial standard components and manufacturing processes
                                                               communications, the data is identified by the date and time that
                  for ‘full-life’ machine support.
                                                               they are generated. The statistical data file can then be saved to
               •  Logical, colour coded Printed Circuit Board (PCB) design
                                                               a memory stick, networked to a computer or emailed.
                  reduces customer engineer training and support.
               Machine operation features
               •  Menu driven from single operator interface.
               •  Fully integrated product codes mean that settings for all
                  inspection processes are automatically adjusted on selection
                  of each product code.
               •  Customisable graphical interface reduces training time
                  and increases operational awareness.
               Management control
               •  Expandable product code support (500 fitted as standard).
               •  ‘Use Case’ configurable security access. Access levels for
                  operators, engineers, supervisors and QA.
               •  Self diagnostic ability to maintain the highest levels of
                  performance.
               •  Performance alerts emailed in real time.
               QA system support
               •  Test piece port as standard.
               •  Easy to use graphical display to support Reject Integrity
                  compliance tests.
               •  Reject Integrity compliance tests logged and available
                  for download or email.
               •  Comprehensive Statistics Set (Audit) generated and stored
                  for download.
               •  Statistics download or email configurable by time, product
                  code changeover or on demand.
               •  Statistics output by eternal IP65 USB, ethernet or by email.
               •  QA alerts emailed in real time.
   1083   1084   1085   1086   1087   1088   1089   1090   1091   1092   1093