Page 25 - Parker - L90LS Mobile directional control valve
P. 25
CH, CHX
Catalogue HY17-8504/UK Mobile Directional Control Valve
Spool Actuators L90LS
CHB3
PC
Service ports to tank
blocked Y2 [76] PC
Stroke length limitation
P-B, A-T Qset B [72]
PCH
Stroke length Pilot restrictor [55A]
limitation
P-A, B-T
Qset A [72] Control signal
P-A, B-T
Control signal
P-B, A-T
Pilot restrictor [55B]
CH, CHX
Pressure compensator, KAS [66]
CHB3
Proportionally remote-controlled actuators, with
enclosed spool-ends and facility for manual control
PC Hydraulic spool-actuator
PC
PCH Hydraulic spool-actuator with facility for supplemen-
tary local lever for direct control PCH
The PC and PCH are proportional, hydraulically PCH
controlled spool actuators with spring-centring to neutral.
They are intended to be controlled by the PCL4 remote- Stroke length limitation
control valve. When determining a suitable control P-B, A-T Qset B [72]
pressure for the PCL4, bear in mind that its breakaway
pressure should be approx. 0,5 bar lower than that of the
directional valve in order to ensure gentle starting and
stopping. The pilot pressure for the PCL4 can be tapped
from the internal pilot-pressure supply in the end section
of the directional valve, via the PS connection.
Breakaway pressure*: 5.5 bar
Final pressure*: 15.0 bar
Permissible pressure in pilot cap: max. 35 bar Stroke length limitation
Connections: G ¼ or 9/16-18 UNF P-A, B-T Qset A [72]
*
The breakaway pressure is the pressure needed for the direc-
tional valve to open the connection “pump to service port”. The
final pressure is the lowest pressure needed to effect full actua-
tion of a spool in the directional valve. This data must be taken
into consideration when choosing control units, since the opening
pressure of the control unit must be lower than the breakaway
pressure of the spool actuator in order to avoid jerky starting and
stopping. However, the control unit’s final pressure must be higher
than the final pressure of the directional valve in order to ensure
that the spools can be fully actuated.
See also separate catalogue for PCL4.
25 Parker Hannifin
Mobile Controls Division Europe
Borås, Sweden