Page 116 - Parker - Vacuum products
P. 116

Catalog 0802-E                                      Pressure Sensors
            Programming Features                                MVS-201 Genius

            Operating modes

                  Mode: OP1 "Air Conservation / Timer                  Mode: OP2 "Vacuum Timer Option"


                                              ON (H-d) Blow-Off                                   ON (H-d) Blow-Off
                   PSI                                                 PSI
                                              OFF (h-d)                                           OFF (h-d)



     B            inHg                        OFF (h-u)               inHg                        OFF (h-u)


                                              ON (H-u) Vacuum                                     ON (H-u) Vacuum
                                              (P-u) Peak Value                                    (P-u) Peak Value

                     ut          dt                                      ut         dt
               Input  ON                                           Input  ON
              Signal OFF                                          Signal OFF
     Selection
       Generator
                                           BT
             Blow-Off  ON     T2                                Blow-Off  ON                  BT
            Solenoid  OFF                                       Solenoid  OFF    T2
                      T1                                                          T1
     CV-CK
             Vacuum  ON             T1                          Vacuum   ON
       MCA, CV,
            Solenoid  OFF                                       Solenoid  OFF
                                                                 Sensor   ON
       CHF
             Sensor   ON                                        Output 1  OFF
            Output 1  OFF                                                  T1: Vacuum Timer
                       T1: Vacuum Timer                                    T2: Blow-Off Delay Timer
                       T2: Blow-Off Delay Timer                            BT: Blow-Off Timer
       MC22
                       BT: Blow-Off Timer
       MC72


            Timer mode OP1                                      Timer mode OP2
       CEK
            “Air conservation / Vacuum valve timer”             “Vacuum valve timer”
            This Vacuum valve control with the use of timing features   This mode is ideal for use with CONVUM generators without
            conserves air consumption via the vacuum generator non-  check valves. Vacuum timer (t1) can be used to control the
       CVXCEK
            return check valve and sensor hysteresis function. Vacuum   vacuum for a specific length of time (0.00 – 9.9sec.) after
            time (t1) can be used to control the vacuum valve for a specific   output 1 is reached. Optional delay timer between vacuum
            length of time (0.0-9.9 sec.) after output 1 vacuum level is   / blow-off (t2) and blow-off (bt) timer is available. After
            reached. The vacuum timing function (t1) will remove the signal   selecting OP2, set bt, t1, and t2 values by using arrow “UP”
       MPS-23
            from the sensor to the vacuum valve allowing the generator   and “DOWN” keys. To bypass any of these timing function
            check valve system to conserve air consumption and vacuum.   operations, simply enter 0.00 seconds and the sensor will
            The vacuum valve will re-open for the same length of time (t1)   automatically proceed to the next function.
       MVS-201
            when the pressure level drops to the hysteresis setting (h-v).
            The operation will continue until the input signal is stopped.
            Optional delay timer between vacuum / blow-off (t2) and blow-
            off (bt) timer is available. After selecting OP1, set bt, t1, and t2
            values by using arrow “UP” and “DOWN” keys. To bypass any
       Generator
     Accessories
            of these timing function operations, simply enter 0.00 seconds
            and the sensor will automatically proceed to the next function.
                                                                  Note:
                                                                  Output Circuit provides vacuum and blow-off confirmation signal
                                                                  (Input Signal to PLC).
       Glossary
                                                                  Input Circuit controls vacuum solenoid valve
                                                                  (Output Signal from PLC).