Page 113 - Parker - Vacuum products
P. 113

Catalog 0802-E                    (Revised 02-01-12)  Pressure Sensors
            Programming Features                               MPS-23 1-Color Generator Mount

            Output type
                                P1 (n1) > P2 (n2)                                         P1 (n1) < P2 (n2)
                 Hysteresis Mode P3 (n3) > P4 (n4)                 Window comparator Mode P3 (n3) < P4 (n4)
                 Output Hysteresis value can be preset.            Within pressure setting range, pressure sensor output can be ON or OFF.
                  Normal open mode                                 Normal open mode
                 Vacuum (MPS-V23)                                  Vacuum (MPS-V23)
                                                                              H = 3 digits
               ON
               OFF                                                ON   H    H
                     P_2 P_1
                     P_4 P_3                                      OFF
                 0                                                   P_1    P_2
                  Vacuum Pressure                                    P_3    P_4
                                                                    0
                 Normal close mode                                   Vacuum Pressure
                 Vacuum (MPS-V23)                                  Normal close mode                                B
                                                                   Vacuum (MPS-V23)
               ON
               OFF                                                ON   H    H
                     n_2 n_1
                     n_4 n_3                                      OFF
                 0                                                   P_1    P_2
                                                                     P_3
                                                                            P_4
                  Vacuum Pressure
                                                                    0
                 (Note)                                              Vacuum Pressure
                 When hysteresis mode setting is within 2 digits, if the input and pre-set                           Generator
                 pressure is quite near, pressure sensor output might cause chattering.                                Selection
            Manual setting mode                                 Auto setting mode                                    MCA, CV,   CV-CK
                                                                   *1. In case of without need of OUT1 pressure value setting, press + at the
              The LED shows: (P_* at normal open mode and (n_*) at normal close mode.  same time to enter (AP2) / (An2).
              Pressure setting value is shown normally and will not lead to pressure sensor  *2. In case of without need of OUT2 pressure value setting, press + at the
              pause or stop working.
                                                                     same time to enter measure mode.                CHF
                                                                   *3. The LED shows (AP*) at normal open mode and (An*) at normal closed mode.
                    1x  Unit setting
                        Press         button one time (1x).           1x  Measure mode
                    OUTPUT 1     Mutually display                         Press         button one time (1x) after setting pressure  MC22
                                             Use the   or    button     value to Auto Setting Mode.
                                             to set desired pressure
                                             setting.                 OUTPUT 1  (*3)
                    1x
                                 Mutually display                                      Prepare auto setting mode at  MC72
                                                                                       OUTPUT1 switch.
                                             Use the   or    button         (*1)
                                             to set desired pressure  1x
                    1x                       setting.                                  Under this mode, the device needs
                     OUTPUT 2    Mutually display                                      to be set repeatedly in order to reach
                                             Use the   or    button                  the auto setting value.       CEK
                                             to set desired pressure  1x
                                             setting.
                    1x                                                OUTPUT 2  (*3)
                                 Mutually display                                      Prepare auto setting mode at  CVXCEK
                                             Use the   or    button         (*2)     OUTPUT2 switch.
                                             to set desired pressure  1x
                                             setting.
                                                                                       Under this mode, the device needs
                                                                                       to be set repeatedly in order to reach  MPS-23
                    1x  Measure mode                                                   the auto setting value.
                                                                      1x  Measure mode
                                                                                                      P1 (n1)  = A - A-B
                                                                   Calculation of setting value       P3 (n3)  4     MVS-201
                                                                   A = The max. pressure value under auto setting mode.  P2 (n2)  = B - A-B
                                                                   B = The min. pressure value under auto setting mode.  P4 (n4)  4
            Error messages
            Error name         Display  Description                          Solutions                               Generator   Accessories
                        OUT1   Er1                                           Turn off power and check the cause of overload
            Excess load                Excess load current of 80 mA          current or lower the current load under 80 mA,
            current error  OUT2  Er2                                         then restart
            Residual pressure error  Er3  During zero reset, ambient pressure is over ±3%   Change input pressure to ambient pressure and
                                       F.S.                                  perform zero reset again                Glossary
                                       The applied pressure is excess the upper limit of
                               – – –
            Applied pressure error     pressure setting                      Adjust the pressure within applied pressure range
                                       The applied pressure is excess the lower limit of
                               – – – –  pressure setting
                               Er4     Internal data error
                                                                             Turn power off and then restart. If error condition
            System Error       Er6     Internal system error                 remains, please return to factory for inspection
                               Er7     Internal data error

                                                            B43                        Parker Hannifin Corporation
                                                                                       Pneumatic Division
                                                                                       Richland, Michigan
                                                                                       www.parker.com/pneumatics