Catalog 0802-E Pressure Sensors
Specifications, Dimensions MPS-23 1-Color Generator Mount
Specifications
Pressure range -101.3 - 0 kPa (-14.5 to 0 PSI)
Proof pressure 0.3 Mpa (44 PSI)
0.1, kPa
0.001, kgf/cm 2
0.001, bar
Display resolution,
Units of measure 0.01, PSI
0.1, inHg
1, mmHg
0.1, mmH 2 O
Media Air & non-corrosive gases, incombustible gases B
Pressure port Generator mount only
Operating temperature 32 to 122°F (0 to 50°C)
Storage temperature -4 to 140°F (-20 to 60°C)
Humidity 40 - 85% RH (no condensation)
Electrical connection (C) 4-pin, M8 connector on 1M lead wire Generator Selection
Power supply 12 to 24VDC ±10% or less, Ripple (Vp-p) 10% or less
Display 3 + 1/2 digit, 1 color, 7-segment RED LED
Display refresh .1 to 3.0 Seconds, Variable (factory set at 0.1)
Control output NPN (Sinking), PNP (Sourcing), Open collector, max 80mA, 2 output MCA, CV, CV-CK
Switch output Output signal, NPN or PNP, Normally open or closed, LED indicator
Output indicator Green LED (OUT1), Red LED (OUT2) CHF
Output modes Hysteresis or Window Comparator
Response time ≤ 2.5ms (chattering-proof function: 24ms, 192ms, 786m selections)
Repeatability ± 0.2% of F.S. ± 1 digit or less MC22
Thermal error ≤ ± 2% of F.S. or less at range of 32 to 122°F (0 to 50°C)
General protection IP40, CE marked, EMC-EN61000-6-2: 2001
Current consumption <55mA
Vibration resistance 10 to 150Hz, Double amplitude 1.5mm, XYZ, 2 hrs. MC72
Shock resistance 980 m/s² (about 10G), 3 times/each directions X, Y, Z
Noise resistance Vp-p400V, 10 ms, 0.5μs noise simulator
Material Housing: ABS (black) , Pressure port: Zinc die-cast, Diaphragm: Silicone CEK
Mass 2.5 oz. (80g) (including cable)
CVXCEK
Dimensions
Generator mount MPS-23
Switch (OUT 1) Switch (OUT 2)
() Button
Use the button to change (Green LED) (Red LED)
setting mode and pre-set
desired value. kPa MVS-201
.65
(16.5)
() Button MODE
Use the button to change
setting mode and pre-set 3-1/2 digit LED display Setting Button .98 Generator Accessories
desired value. (25)
Display the measured Change setting mode and
pressure value, each set pre-set final desired value
content and error code.
.43 2.17 38.9
M2x0.4 (11) (55) (990) Glossary
Ø 5
Ø 8
.98
(25)
.65 For mounting on Generator
(16.5)
B41 Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics