Page 111 - Parker - Vacuum products
P. 111

Catalog 0802-E                                     Pressure Sensors
            Specifications, Dimensions                         MPS-23 1-Color Generator Mount

            Specifications
            Pressure range                         -101.3 - 0 kPa (-14.5 to 0 PSI)
            Proof pressure                         0.3 Mpa (44 PSI)
                                                   0.1, kPa
                                                   0.001, kgf/cm 2
                                                   0.001, bar
            Display resolution,
            Units of measure                       0.01, PSI
                                                   0.1, inHg
                                                   1, mmHg
                                                   0.1, mmH 2 O
            Media                                  Air & non-corrosive gases, incombustible gases                   B
            Pressure port                          Generator mount only
            Operating temperature                  32 to 122°F (0 to 50°C)
            Storage temperature                    -4 to 140°F (-20 to 60°C)
            Humidity                               40 - 85% RH (no condensation)
            Electrical connection                  (C) 4-pin, M8 connector on 1M lead wire                           Generator   Selection
            Power supply                           12 to 24VDC ±10% or less, Ripple (Vp-p) 10% or less
            Display                                3 + 1/2 digit, 1 color, 7-segment RED LED
            Display refresh                        .1 to 3.0 Seconds, Variable (factory set at 0.1)
            Control output                         NPN (Sinking), PNP (Sourcing), Open collector, max 80mA, 2 output  MCA, CV,   CV-CK
            Switch output                          Output signal, NPN or PNP, Normally open or closed, LED indicator
            Output indicator                       Green LED (OUT1), Red LED (OUT2)                                  CHF
            Output modes                           Hysteresis or Window Comparator
            Response time                          ≤ 2.5ms (chattering-proof function: 24ms, 192ms, 786m selections)
            Repeatability                          ± 0.2% of F.S.  ± 1 digit or less                                 MC22
            Thermal error                           ≤ ± 2% of F.S. or less at range of 32 to 122°F (0 to 50°C)
            General protection                     IP40, CE marked, EMC-EN61000-6-2: 2001
            Current consumption                    <55mA
            Vibration resistance                   10 to 150Hz, Double amplitude 1.5mm, XYZ, 2 hrs.                  MC72
            Shock resistance                       980 m/s² (about 10G), 3 times/each directions X, Y, Z
            Noise resistance                       Vp-p400V, 10 ms, 0.5μs noise simulator
            Material                               Housing: ABS (black) , Pressure port: Zinc die-cast, Diaphragm: Silicone  CEK
            Mass                                   2.5 oz. (80g) (including cable)
                                                                                                                     CVXCEK

            Dimensions
            Generator mount                                                                                          MPS-23
                                                       Switch (OUT 1)   Switch (OUT 2)
                       () Button
                       Use the  button to change       (Green LED)      (Red LED)
                       setting mode and pre-set
                       desired value.                              kPa                                               MVS-201
                                                                                                    .65
                                                                                                   (16.5)
                       () Button                                  MODE
                       Use the  button to change
                       setting mode and pre-set  3-1/2 digit LED display  Setting Button    .98                      Generator   Accessories
                       desired value.                                                       (25)
                                        Display the measured  Change setting mode and
                                        pressure value, each set  pre-set final desired value
                                        content and error code.
                                           .43           2.17                      38.9
                                  M2x0.4   (11)          (55)                      (990)                             Glossary
                       Ø 5
                                    Ø 8
                     .98
                     (25)


                              .65                 For mounting on Generator
                             (16.5)

                                                            B41                        Parker Hannifin Corporation
                                                                                       Pneumatic Division
                                                                                       Richland, Michigan
                                                                                       www.parker.com/pneumatics
   106   107   108   109   110   111   112   113   114   115   116