Page 112 - Parker - Vacuum products
P. 112
Catalog 0802-E Pressure Sensors
Programming Features MPS-23 1-Color Generator Mount
Initial setting mode
1. Unit setting
Press button for more than 3 seconds.
1x 4. Response time setting
Model: MPS-V23
2.5ms 24ms 192ms 768ms
MpA kgf/cm 2 bar psi inHg mmHg mmH 2 O Use the or button to select response time.
Use the or button to set desired
pressure unit. 1x 5. Pressure value setting: auto / manual
B 1x 2. Out 1 mode setting
Manual Auto
Setting Setting
NO Mode NC Mode Mode Mode
Use the or button to set OUT1 mode. Use the or button to select auto / manual.
Output Type:
NO: Normal open mode 1x Measure mode
NC: Normal closed mode
Selection
Generator
1x 3. Out 2 mode setting
NO Mode NC Mode
CV-CK
MCA, CV,
Use the or button to set OUT1 mode.
Output Type:
NO: Normal open mode
CHF
NC: Normal closed mode
MC22
MC72
CEK
Zero point setting / the max. & min. display Key lock / unlock mode
mode
Key lock / unlock mode
CVXCEK
Zero setting: Press button for less than 5 seconds.
• press the button at the same time until the “00” is
shown. Release the button to end zero setting. Use the or button to
Lock
MPS-23
The max. value display mode: Unlock Mode select Lock / Unlock Mode.
Mode
• Press button 2 seconds to enter the max. value mode, 1x Measure mode
pressure sensor will detect the max. value and keep max.
value displayed. • Key lock mode can prevent operation mistakes.
MVS-201
• Press button 2 seconds to return to measure mode
display.
The min. value display mode:
• Press button 2 seconds to enter the min. value mode,
Generator
Accessories
pressure sensor will detect the min. value and keep min.
value displayed.
• Press button 2 seconds to return to measure mode
display.