Page 89 - Schroeder - Accessories
P. 89
Electronic Level Switch
Air Breathers
■ Switching mode of the switching outputs ■ Switch-on delay adjustable from 0-20 seconds Additional
adjustable (switching point function or window ■ Energy saving mode
function) Functions Suction
■ Switching direction of the switching outputs Separators
adjustable (N/C or N/O) and
Strainers
Oil Sight
The grey areas show the detection range for a very large reflector, e.g. a fluid surface, providing the sensor is Recording Glasses
ideally positioned. Outside the grey area, it is not possible to evaluate the ultrasonic reflections.
Ranges
Operational scanning range 280 mm: Operational scanning range 480 mm: Electronic
Sensors
Fluid Level
Indicators
Plate Plate
Round bar
Ø 11 mm Round bar
Ø 27 mm
Operational scanning range 1600 mm: Operational scanning range 4000 mm:
Plate
Plate
Round bar
Ø 27 mm
Round bar
Ø 27 mm
Operational scanning range 6400 mm:
Plate
Round bar
Ø 27 mm
SCHROEDER INDUSTRIES 87